;-----------------------------------------------------------------------------\ ; ADCP Command File for use with VmDas software. ; ; ADCP type: 75 Khz Ocean Surveyor ; Setup name: default ; Setup type: Low resolution, long range profile(narrowband) ; ; NOTE: Any line beginning with a semicolon in the first ; column is treated as a comment and is ignored by ; the VmDas software. ; ; NOTE: This file is best viewed with a fixed-point font (e.g. courier). ; Modified Last: 12August2003 ;----------------------------------------------------------------------------/ ; Restore factory default settings in the ADCP cr1 ; set the data collection baud rate to 38400 bps, ; no parity, one stop bit, 8 data bits ; NOTE: VmDas sends baud rate change command after all other commands in ; this file, so that it is not made permanent by a CK command. cb611 ; Set for narrowband single-ping profile mode (NP), fifty (NN) 16 meter bins (NS), ; 8 meter blanking distance (NF) WP0 NN050 NP00001 NS1600 NF0800 ; DISABLE single-ping bottom track (BP), ; Set maximum bottom search depth to 1200 meters (BX) BP000 BX12000 ; output velocity, correlation, echo intensity, percent good ND111100000 ; One and a half seconds between bottom and water pings TP000150 ; Three seconds between ensembles ; Since VmDas uses manual pinging, TE is ignored by the ADCP. ; You must set the time between ensemble in the VmDas Communication options TE00000150 ; Set to calculate speed-of-sound, no depth sensor, external synchro heading ; sensor, no pitch or roll being used, no salinity sensor, use internal transducer ; temperature sensor EZ1020001 ; Output beam data (rotations are done in software) EX00000 ; Set transducer misalignment (hundredths of degrees) CHECK THIS EA04500 ; Set transducer depth (decimeters) CHECK THIS: ED00050 ; Set Salinity (ppt) ES35 ; save this setup to non-volatile memory in the ADCP CK